Peripheral angioplasty catheter LOVIX OTW/RX

Peripheral angioplasty catheter, OTW, Lovix, is intended for dilating of de novo or restenotic atherosclerotic lesions in patients with symptomatic peripheral artery disease as well as for the post-delivery expansion of a peripheral stent (postdilatation).

Lovix peripheral angioplasty catheter, OTW, consists of:

  • Y- hub;
  • dual lumen polyamide tube (first lumen for guidewire, second for filling balloon);
  • polyamide balloon.

It has two radiopaque markers to identify cylindrical portion of the balloon, that enables the stent positioning within the treated lesion.

Peripheral angioplasty catheter LOVIX RX consists of:

  • distal part – has a dual lumen. The outer lumen is used to inflate the balloon, and the inner lumen is used for moving the catheter over a guidewire. The distal section of the catheter has a hydrophilic coating. At the end of the catheter there is a semi-compliant balloon with two radiopaque markers allowing placing of the balloon in relation to treated lesion. The balloon is designed to inflate to a defined diameter at recommended pressure.
  • proximal part – consists of a stainless steel hypotube covered with fluoropolymer and a hub with a single female luer-lock connector for inflation and deflation of the balloon.

The balloon is delivered to the intended lesion site and inflated, restoring patency of the vessel.

Intended purpose:

Peripheral Angioplasty Catheter Lovix is intended for dilating of de novo or restenotic atherosclerotic lesions in patients with symptomatic peripheral artery disease, as well as for the post-delivery expansion of a peripheral stent (postdilatation).

Technical data overview

WITH DELIVERY SYSTEM OVER THE WIRE (OTW)

Balloon material  polyamide
Balloon diameter 1.50-16.00 mm
Balloon length 20-250 mm
Nominal pressure (for balloon diameters 1.50-4.00  mm) 10 atm
Nominal pressure (for balloon diameters 5.00-7.00  mm) 8 atm
Nominal pressure (for balloon diameters 8.00-16.00 mm)  6 atm
Delivery system  Over The Wire (OTW)
Delivery system lengths 80 cm, 100 cm, 110 cm, 120 cm, 135 cm, 170 cm

WITH DELIVERY SYSTEM RAPID EXCHANGE (RX)

Balloon material  polyamide
Balloon diameters  1.25-7.00 mm
Balloon lengths  10-250 mm
Nominal pressure (for balloon diameters 1.25-4.50 mm) 10 atm
Nominal pressure (for balloon diameters 5.00-7.00 mm) 8 atm
Compatible guidewire   max 0.014”
Delivery system  Rapid Exchange (RX)
Delivery system lengths 140 cm

Available versions

WITH DELIVERY SYSTEM OVER THE WIRE (OTW)

Reference: Nominal balloon Nominal balloon Use with guidewire Use with Catheter length Nominal pressure
diameter [mm] length [mm] introducer [F] [cm] [atm]
B C E
PBABxCE110 1.5 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.018 4 110 10
0.025
PBABxCE110 1.5 120, 150, 200, 250 0.025 4 110 10
PBABxCE110 2 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.018 4 110 10
0.025
PBABxCE110 2 120,150, 200, 250 0.025 4 110 10
PBABxCE110 2.5 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.018 4 110 10
0.025
PBABxCE110 2.5 120, 150, 200, 250 0.025 4 110 10
PBABxCE110 3 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.018 4 110 10
0.025
PBABxCE110 3 120, 150, 200, 250 0.025 4 110 10
PBABxCE110 4 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.018 5 110 10
0.025
0.035
PBABxCE110 4 120, 150, 200, 250 0.035 5 110 10
PBABxCE110 5 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.025 5 110 8
0.035
PBABxCE110 5 120 0.025 5 110 8
PBABxCE110 5 150, 200, 250 0.035 6 110 8
PBABxCE110 6 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.025 5 110 8
0.035
PBABxCE110 6 120 0.025 6 110 8
PBABxCE110 6 150, 200, 250 0.035 6 110 8
PBABxCE110 7 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95,100, 0.035 5 110 8
PBABxCE110 7 120, 150,200, 250 0.035 6 110 8
PBABxCE110 8 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.035 5 110 6
PBABxCE110 9 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.035 6 110 6
PBABxCE110 10 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.035 6 110 6
PBABxCE110 12 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.035 7 110 6
PBABxCE110 14 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.035 8 110 6
PBABxCE110 16 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.035 8 110 6

WITH DELIVERY SYSTEM RAPID EXCHANGE (RX)

 

Reference: Nominal Minimum Guiding Nominal Nominal
balloon diameter Catheter I.D. pressure balloon length
[mm] [inch] [atm] [mm]
B C
PBARXBxC140 1.25 0.056 10 10, 15, 20, 25, 30, 35, 40
PBARXBxC140 1.5 0.056 10 10, 15, 20, 25, 30, 35, 40
PBARXBxC140 1.75 0.056 10 10, 15, 20, 25, 30, 35, 40
PBARXBxC140 2 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 2.25 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 2,5 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 2.75 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 3 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 3.25 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 3.5 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 3.75 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 4 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 4.5 0.064 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 5 0.067 8 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 5.5 0.067 8 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 6 0.067 8 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 6.5 0.067 8 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250
PBARXBxC140 7 0.071 8 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250